Description:
- Fluke 373 True-RMS AC Clamp Meter is a great choice for AC-only current measurement situations. Featuring True RMS AC voltage and current measurements you can measure AC current to 600 A and AC voltage to 600V. The 373 also measures DC voltage to 600 V and resistance to 6000 Ω.
- To make it even easier to use, the large, easy-to-read backlit display provides better visibility in dimly lit conditions. And the 373 automatically sets the correct measurement range based on the voltage present when you power up, so you do not need to move the switch while taking a measurement. When you put it all together, you’ll find the Fluke 373 offers everything you need, plus a little more
Features:
- 600 A ac current measurement with fixed jaw
- 600 V ac and dc voltage measurement
- State of the art signal processing allows for use in noisy electrical environments while providing stable readings
- CAT IV 300 V, CAT III 600 V
- True-rms ac voltage and current for accurate measurements on non-linear signals
- Large, easy to read backlight display automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
- Soft carrying case
Specifications:
- AC Current
- Range 600.0 A
- Resolution 0.1 A
- Accuracy 2 % ± 5 digits (48 – 62 Hz)
- Crest Factor (50/60 Hz) 2.5 @ 600 A
- AC Voltage
- Range 600.0 V
- Resolution 0.1 V
- Accuracy 1.0 % ± 5 digits (48 – 62 Hz)
- DC Voltage
- Range 600.0 V
- Resolution 0.1 V
- Accuracy 1 % ± 5 digits
- Resistance
- Range 600.0 Ω/6000 Ω
- Resolution 0.1 Ω/1 Ω
- Accuracy 1 % ± 5 digits
- Continuity Beeper 30 Ω
- Capacitance
- Range 10.0 – 100.0 μF / 1000 μF
- Resolution 0.1 μF/1 μF
- Accuracy 1.9 % ± 2 digits
- Mechanical Specifications
- Size (L x W x H) 232 mm x 85 mm x 45 mm
- Weight 370 g
- Environmental Specifications
- Operating Temperature -10 °C to +50 °C
- Storage Temp -40 °C to +60 °C
- Operating Humidity Non condensing (< 10 °C)
- ≤ 90 % RH (at 10 °C to 30 °C)
- ≤ 75 % RH (at 30 °C to 40 °C)
- ≤ 45 % RH (at 40 °C to 50 °C)
- (Without Condensation)
- Operating Altitude 3000 meters
- Storage Altitude 12,000 meters
- EMI, EMC Meets all applicable requirements in EN61326-1:2006
- Temperature Coefficients Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C
- Safety Compliance ANSI/ISA S82.02.01:2004
- CAN/CSA-C22.2 No. 61010-1-04
- IEC/EN 61010-1:2001, 600V CAT III, 300V CAT IV
- Pollution Degree 2
- EN/IEC 61010-2-32:2002
- EN/IEC 61010-031:2002/A1:2008
- Agency Approvals
- Batteries 2 AA, NEDA 15A, IEC LR6
Includes:
- Coated instruction card
- Safety information sheet
- Soft carrying case
- TL75 test leads
- Five AA Alkaline batteries
UPC:
- 095969557832